Červenka Consulting

Modelling of Large-Scale SFRC/RC Beams Using ATENA at University of New South Wales, Australia

ATENA 2D analysis of four large-scale steel fibre reinforced concrete beams with stirrups failing in shear, tested at the University of New South Wales.

Ali Amin, Stephen J. Foster
University of New South Wales, Sydney, Australia

Large-scale steel fibre reinforced concrete beams with conventional stirrups were tested in shear at UNSW and analysed with the smeared crack model of ATENA 2D. The tensile law of the fibre reinforced concrete was derived by inverse analysis of prism bending tests. The model was validated against four large-scale beams and reproduced their measured response. The authors conclude that ATENA models the behaviour of these beams when an appropriate tensile law is used, and that the model can serve as a basis for design procedures for fibre reinforced concrete members failing in shear.

ATENA principal strains and observed crack pattern of beam B25-10-450
Beam B25-10-450: maximum principal strain in ATENA at 7 mm deflection (a), at peak load (b) and at 15 mm (c); crack pattern of the tested beam at failure (d). Figure: Amin and Foster (2014).

A. Amin, S. J. Foster. Numerical modelling of large scale steel fibre reinforced-reinforced concrete beams failing in shear. FRC 2014 Joint ACI-fib International Workshop: Fibre Reinforced Concrete, from Design to Structural Applications, 2014. Abstract (PDF)